Does the drive cycle dynamometer test lead to either stopped or overspeeded motor?

Posted on February 26, 2019

In the latest technical reference under point 22.h.iii you describe the drive cycle. There has been a question about this point before, but was not fully answered to our understanding. The drive cycle is created …

Posted in UncategorizedLeave a comment

Should the speed limit of 2500rpm be enabled during the “field test on actual bicycle”?

Posted on February 13, 2019

At present, we expect that the 2500 rpm limit to be enabled during the field test.

Posted in UncategorizedLeave a comment

Continuous output power?

Posted on February 13, 2019

In order for the device to provide continuous output power of 500W the motor would need to run at around 3750rpm. (Power of the electronic load = Xrpm/3000rpm *40V*10A). What is the purpose of the …

Posted in UncategorizedLeave a comment

Are there specific simulation and experimental results that should be provided in the progress report or we should enclose the most striking ones based on our own choice?

Posted on February 13, 2019

Will there be a more detailed description of the required contents of the progress report as there was for the Design proposal or will there not be anymore updates on the document which contains guidelines …

Posted in UncategorizedLeave a comment

Under which operating conditions will the hot spot and case temperature be measured?

Posted on February 13, 2019

It would be reasonable to assume that the hot spot and case temperature test would be performed with the device running at maximum continuous output power of 500W, but it has been stated that the …

Posted in UncategorizedLeave a comment

What is meant by “enter fault mode” at free acceleration test (most recent Technical Reference Document 22f)?

Posted on February 13, 2019

It has not been specified what’s supposed to happen in the fault mode. Should we turn the device off when the speed reaches 2500rpm or just prevent the device from working at speeds above 2500rpm? …

Posted in UncategorizedLeave a comment

How will the fault protection be tested? How will it be judged?

Posted on February 13, 2019

When the fault conditions are reached, the system will have to provide an indication should be made as required in the technical reference document item 14.E. How the system responds to the fault event to …

Posted in UncategorizedLeave a comment

Drive cycle and range performance test?

Posted on February 13, 2019

With a selected output power as specified under 22.b.iii and the specified speed limit of 2500rpm there is a maximum output power (of the electronic load) which can be calculated as 2500rpm/3000rpm*40V*Iout. The throttle signal …

Posted in UncategorizedLeave a comment

What’s the dead time of Progress Report

Posted on February 13, 2019

March 7th 2019

Posted in UncategorizedLeave a comment

Workshop-the 17th or the 19th of March?

Posted on February 13, 2019

In the provided IFEC Workshop agenda it is stated that the workshop takes place on the 17th of March. In the post about announcement of the second round competition teams it is stated that the …

Posted in UncategorizedLeave a comment
  • You're on page 1
  • 2
  • 3
  • 4
  • Next page

Site footer content

University logo that links to main university website

Contact Us

  • University of Wisconsin - Madison
    1415 Engineering Dr.
    Madison, WI 53706
  • Email: giri@engr.wisc.edu

Website feedback, questions or accessibility issues: kyle.hanson@wisc.edu.

Learn more about accessibility at UW–Madison.

This site was built using the UW Theme | Privacy Notice | © 2023 Board of Regents of the University of Wisconsin System.